Figure
Once the lamp housing is installed into the lamp base, tighten the four screws that you loosened in the previous step.
2.Install the two screws that secure the lamp housing to the carriage cover (see screws B in Figure
3.Connect the auxiliary cable to the top of the lamp. See Figure
4.Connect the lamp power cable to the side of the lamp. See Figure
Re-install the service-end lamp housing
1.Secure the lamp housing to the lamp assembly using the original two silver screws on the service end of the carriage (see screws A in Figure
If you have difficultly fitting the lamp housing back onto the lamp base, see “Installing the User- End Carriage Lamp”
2.Install the two
3.Connect the auxiliary cable to the top of the lamp. See Figure
4.Connect the lamp power cable to the side of the lamp. See Figure
5.Power up the printer.
Clean the rail encoder strip (bi-weekly)
Ink dust and debris can accumulate on the encoder strip and block accurate reading of the encoder marks by the carriage encoder reader.
66 Chapter 9 User cleaning | ENWW |