![](/images/backgrounds/286380/hp-scitex-fb500-industrial-printer-users-manual-15555038x1.png)
To switch to the Printing page, press the Printing icon in the Activity Tray at the bottom of the screen.
1Status messages
●Stored Jobs status — current mode (print and save, print only, save only), number of stored jobs, number of locked jobs. See Stored jobs on page 23 for details.
●UV Lamps
2Jobs — displays the Stored Jobs feature. See Stored jobs on page 23 for details.
3Options — displays the Printer Options menu. See Printing Options menu on page 32 for details.
4Calibrate — displays the Calibrate Printer menu. See Calibrate the printer on page 45 for details.
5Turn On Lamps/Turn Off Lamps — enables you to manually switch the UV curing lamps on and off.
Printing Options menu
●Print Position and Eject Settings — this menu option controls two related functions that enable you to control how print jobs are positioned on
◦Position — when the printed image does not span the entire width of the media, positions the printed image flush left (nearest the control panel or user side), flush right, centered, or nested on the media (if Auto Eject Off is selected).
◦Eject — you can choose whether the media is ejected to the output or input side after each job prints, or disable automatic eject.
See Position and eject options on page 25 for further details.
●Space Between Prints
●Measure Media
◦Measure only on first load — measure only once, after you configure the media; best for fast throughput when precise image placement is not required or when using the media alignment pins
◦Measure on all loads — best for precise image placement, such as for
◦Don’t measure media — best for fast throughput when precise image placement is not required and there are very wide margins around the image
After you select one of these options, the printer prompts you to select a measurement type:
◦Minimal — measures the width of the media once and finds the front right edge; no skew detection
◦Standard — measures the width of the media once, and finds the front edge in two places to estimate skew
◦One Edge — (available with Measure on all loads is selected) measures the user- and
◦Maximal — measures the width of the media in two places to estimate skew
32 Chapter 6 Use the control panel | ENWW |