3.Install the spring-loaded clamp’s dowels (A and B below) into the reflector. Figure 9-9Installing the dowels into the reflector

4.Repeat this procedure for the other lamp.

Re-install the lamp housings

Re-install the user-end lamp housing

1.Secure the lamp housing to the lamp assembly using the original two lower silver screws on the user end of the carriage (see screws A in Figure 9-3 User end screws on page 61 for locations).

If you have difficultly fitting the lamp housing back onto the lamp base, loosen the four screws indicated below.

If the lamp housing is still difficult to install, squeeze the side of the lamp base to bend the side in about 0.8 mm (0.031 in).

Figure 9-10Loosening screws to ease installation

ENWW

Replace UV lamp bulb (500–1000 hours) 65