Model 3555B

Section V

SECTION V

MAINTENANCE

5-1. INTROOUCTION.

5-2. This section of the manual contains information necessary in the maintenance of the -hp- Model 3555B Transmission and Noise Measuring Set. Included are performance checks, adjustment and calibration procedures and troubleshooting.

5-3. The test equipment needed to properly maintain and service the Model 3555B is listed in Table 5-1.Included in Table 5-1is the equipment to be used, required specifications 'and recommended model. If the recommended model is not available other equipments

can be substituted provided they meet the required specifications.

5-4. FACTORY SELECTED VALUES.

5-5. Factory selected values are denoted on the schematic diagrams by an asterisk. The nominal value is shown. The value in your instrument may be different or the part may be omitted.

5-6. 150 BAL CONVERSION.

a.To convert the 135 BAL function to a 150

BAL

Table 5-1. Required Test Equipment

INSTRUMENT

 

RECOMMENDED

TYPE

REQUIRED CHARACTERISTICS

MODEL

Oscillator

Frequency Range: 20Hz to 3MHz

-hp- 654A

 

Levels: -80dBm to +30dBm

 

 

Accuracy: ±0.1 5dB

 

Oscillator

Frequency Range: 100Hz to 20kHz

-hp- 201 C

 

Amplitude: 30V

 

Transformer

Line matching

-hp- 11004A

Voltmeter,

Function: AC and DC

-hp- 3440A/3445A

digital

Accuracy: ±.1%

 

Amplifier

Voltage gain: 20 dB

-hp- 467A

Output:

+/-20V peak at 0.5A peak

 

Voltmeter, AC

Frequency Range: 20Hz-4MHz

-hp- 400FL

 

Accuracy: ±2%

 

Termination

50 ohms ±.25%

-hp- 11048B

Termination

75 ohms ±.25%

-hp- 11094A

Cables

Balanced BNC to 310 plug

See Figure 5-1.

Adapter

BNC to 358 plug

Trompeter Electronics

 

 

No. AD-1W

Resistors

576 ohms ±1% (1)

-hp- Part No. 06984598

 

875 ohms ±1% (1)

(Use 825 ohm, 0757-0731 and

 

 

49.9 ohm, 0698A4110 in series)

 

300 ohms 0.1 % (4)

-hp- Part No. 0698-6295

 

600 ohms ±0.1% (4)

-hp- Part No. 0698-7408

 

135 ohms ±0.1%(4)

-hp- Part No. 0698-7364

 

75 ohms ±0.1% (4)

-hp- Part No. 0698-7363

 

900 ohms ±0.1%

Use 600 and 300 in series (0.1%)

 

150 ohms ±.1% (2)

-hp- Part No. 0698-6774

 

100 kilohms 1% (1)

-hp- Part No. 0757-0465

 

 

 

 

 

 

 

5-1

 

Page 35
Image 35
HP TM 11-6625-2779-14&P Section Maintenance Introouction, Factory Selected Values, BAL Conversion, Required Test Equipment