www531374..reelsche-1 A - 947 Man.qxd 2/15/2005matic7:54..coPM Pagem84

900 Series™ Defaults to Simulator with a Transducer Attached

A connected and functioning transducer will cause the newly-started 900 Series™ to go into Normal operating mode automatically. If, when you power up the 900 Series™, it goes into Simulator mode automatically, even though a transducer is already connected, this means that the control head is not detecting the transducer. Perform the following troubleshooting tasks:

Using the Installation Guide that also comes with your 900 Series™, check to make sure that the transducer cable is securely connected to the 900 Series. Reconnect if necessary, and power up the 900 Series™ again to see if this fixes the problem.

Replace the non-functioning transducer with a known good transducer if available and power up the control head again.

Check the transducer cable. Replace the transducer if the cable is damaged or corroded.

79

Page 84
Image 84
Humminbird 531374-1_A manual Series Defaults to Simulator with a Transducer Attached