Specifications
This section lists the physical specifications for your computer.
Dimensions
Height: 398 mm (15.67 in.)
Width: 180 mm (7.08 in.)
Depth: 402 mm (15.82 in.)
Weight
Minimum configuration as shipped: 7.6 kg (16.8 lb)
Maximum configuration: 9.97 kg (22 lb)
Environment
Air temperature:
System on: 10° to 35°C (50° to 95° F)
System off: 10° to 43°C (50° to 110° F)
Maximum altitude: 2134 m (7000 ft)
Note: The maximum altitude, 2134 m (7000 ft), is the maximum altitude at which the specified air temperatures apply. At higher altitudes, the maximum air temperatures are lower than those specified.
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Electrical input
Input voltage:
Low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input frequency range:
Voltage switch setting: 115 V ac
High range:
Minimum: 200 V ac
Maximum: 240 V ac
Input frequency range:
Voltage switch setting: 230 V ac
Input
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.30 kVA
Note: Power consumption and heat output vary depending on the number and type of optional features installed and the
Heat output (approximate) in British thermal units (Btu) per hour:
Minimum configuration: 257 Btu/hr (75 watts)
Maximum configuration: 785 Btu/hr (230 watts)
Airflow
Approximately 0.68 cubic meters every minute (24 cubic feet every minute) maximum
Acoustical noise-emission values
For microprocessors less than 2.8 GHz:
Average
At operator position:
Idle: 28 dBA
Operating: 35 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 25 dBA
Operating: 33 dBA
Declared (upper limit)
Idle: 4.0 bels
Operating: 4.7 bels
For microprocessors greater than or equal to 2.8 GHz:
Average
At operator position:
Idle: 33 dBA
Operating: 35 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 30 dBA
Operating: 33 dBA
Declared (upper limit)
Idle: 4.4 bels
Operating: 4.7 bels
Note: These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual