EM78M611E
Universal Serial Bus Series Microcontroller
30
Product Specification (V1.1) 11.22.2006
(This specification is subject to change without further notice)
ERA [0~4]: AD Channel Selector
AD4 AD3 AD2 AD1 AD0 Channel I/O Port
0 0 0 0 0 0 P50
0 0 0 0 1 1 P51
0 0 0 1 0 2 P52
0 0 0 1 1 3 P53
0 0 1 0 0 4 P54
0 0 1 0 1 5 P55
0 0 1 1 0 6 P56
0 0 1 1 1 7 P57
0 1 0 0 0 8 P80
0 1 0 0 1 9 P81
0 1 0 1 0 10 P82
0 1 0 1 1 11 P83
0 1 1 0 0 12 P84
0 1 1 0 1 13 P85
0 1 1 1 0 14 P86
0 1 1 1 1 15 P87
1 0 0 0 0 16 P60
1 0 0 0 1 17 P61
1 0 0 1 0 18 P62
1 0 0 1 1 19 P63
1 0 1 0 0 20 P64
1 0 1 0 1 21 P65
1 0 1 1 0 22 P66
1 0 1 1 1 23 P67
ERA [7] AD Converter ready flag 0 1: Start AD Conversion (set by firmware). 1 0: When AD conversion is finished and has moved digital data into the AD Data Register, this bit will be set by hardware.
NOTE
Hardware can enable this function only at AD Channel Select of the functional I/O port.
After a power-on reset, the initial value of this register is 0b0001_1111.
ERB (AD LSB Data Register) Default Value: (0B_0000_0000)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit 1 Bit 0 0 0 0 0 0 0
8 bits AD LSB Digital Data