EM78M611E

Universal Serial Bus Series Microcontroller

C Code Option Register

EM78M611E has two Code option registers, which are not part of the normal program memory. The option bits cannot be accessed during normal program execution.

Address 000:

Bit

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

ID_8

ID_7

ID_6

ID_5

ID_4

ID_3

ID_2

ID_1

ID_0

OST_1

OST_0

Frequency

/Protect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address 001:

Bit

 

5

4

 

3

 

2

 

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

/AD_Hold

/R.S.

Package_1

Package_0

 

 

 

 

 

 

 

 

 

 

 

 

Bit

12

11

10

9

8

7

6

Mnemonic

QTP_Code1

QTP_Code0

EP2_

EP2_

EP2_

EP2_

EP2_

Maxsize_2

Maxsize_1

Maxsize_0

DIR

Enable

 

 

 

Address 000:

Bit 1 (Frequency) : Frequency Selection 0 : MCU run on 12 MHz

1 : MCU run on 6 MHz

Bits 3~2 (OST_1 ~ OST_0) : Oscillator start-up time. 00 : 500µs

01 : 2ms

10 : 8ms

11 : 16ms Bits 4~12 : User ID

Address 001:

Bits 1~0 (Package_1 ~ Package_0) : Package type selection 00 : Not defined

01 : 40 pins

10 : Not defined

11 : 44 pins

Bits 3~2 : Reserved bits

Product Specification (V1.11) 04.20.2007

39

(This specification is subject to change without further notice)

Page 43
Image 43
IBM EM78M611E manual Code Option Register, 11 16ms Bits 4~12 User ID Address