8.2.3.3IOC5 ~IOC9 I/O (Port Direction Control Registers) Default Value: (0B_1111_1111)
These are I/O port (Port 5 ~ Port 7) direction control registers. Each bit controls the I/O direction of three I/O ports respectively. When these bits are set to 1, the relative I/O pins become input pins. Similarly, the I/O pins becomes outputs when the relative control bits are cleared.
0 : Output direction
1 : Input direction
8.2.3.4IOCA (Operation Mode Control Register) Default Value: (0B_1110_0000)
Bit 7 | Bit 6  | Bit 5  | Bit 4  | Bit 3  | Bit 2  | Bit 1  | Bit 0  | 
Dual_Frq.1  | Dual_Frq.0  | -  | Remote_Wake up  | ExReg_Sel  | PDA  | PS/2 | USB  | 
IOCA [0, 1] These two bits are used to select the operation mode.
IOCA[1]  | IOCA[0]  | 
  | Operation Mode | 
  | |||
  | 
  | 
  | 
  | 
0  | 0  | 
  | Detect Mode  | 
  | 
  | 
  | 
  | 
0  | 1  | 
  | USB Mode  | 
  | 
  | 
  | 
  | 
1  | 0  | 
  | PS/2 Mode  | 
  | 
  | 
  | 
  | 
1  | 1  | 
  | USB Test Mode  | 
IOCA[2] | Pattern Detect Application function enable bit. This bit is used to enable the  | 
  | Pattern Detect Application (PDA) function. For details about this function  | 
  | refer to Section 8.11.  | 
  | 0 : Disable PDA function  | 
  | 1 : Enable PDA function  | 
IOCA[3] | Extra control register select bit. The five extra control registers (REA, REB,  | 
  | REC, RED, and REE) are located in 0xA~0xE. To access these five  | 
  | registers, set the bit as follows:  | 
  | 0 : Select RA~RE  | 
  | 1 : Select Extra Control register ERA~ERE  | 
IOCA[4] | Indicate whether the device is currently requested to support remote wake  | 
  | up or not. The Remote   | 
  | ClearFeature () requests.  | 
0 : Do Not support remote wake up
1 : Supports remote wake up
NOTE
IOCA[4]: Remote_Wake up bit
EM78M611 do NOT support this function. Only EM78M611E does.