3.3.2Array Performance Features
Table 3.4 shows the MegaRAID 8480 Storage Adapter array performance
features. |
|
|
|
Table 3.4 | Array Performance Features | ||
|
|
| |
Specification |
| MegaRAID 8480 RAID Controller | |
|
|
| |
PCI Express Host Data Transfer | 2.5 | Gbits/s per lane | |
Rate |
|
|
|
|
|
| |
Drive Data Transfer Rate | 3.0 | Gbits/s per lane | |
|
| ||
Maximum Scatter/Gathers | 26 elements | ||
|
|
| |
Maximum Size of I/O Requests | 6.4 | Mbytes in 64 Kbyte stripes | |
|
| ||
Maximum Queue Tags per Drive | As many as the drive can accept | ||
|
|
| |
Stripe Sizes |
| 8, 16, 32, 64, or 128 Kbyte | |
|
|
| |
Maximum Number of Concurrent | 255 |
| |
Commands |
|
|
|
|
|
| |
Support for Multiple Initiators | Yes |
| |
|
|
|
|
3.3.3Fault Tolerance
Table 3.5 shows the fault tolerance features of the Megaraid 8480
Storage Adapter. |
| |
Table 3.5 | Fault Tolerance Features | |
|
|
|
Specification |
| MegaRAID 8480 RAID Controller |
|
| |
Support for SMART1 | Yes | |
Optional Battery Backup for | LSIiTBBU02 battery backup. 4.8V/880mAH | |
Cache Memory | battery pack; up to 72 hours of data retention | |
|
| for 256 Mbytes |
|
| |
Drive Failure Detection | Automatic | |
|
| |
Drive Rebuild Using Hot Spares | Automatic | |
|
| |
Parity Generation and Checking | Yes | |
|
|
|
1.The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all predictable disk drive failures. In addition, SMART monitors the internal performance of all motors, heads, and drive electronics.
MegaRAID 8480 Storage Adapter Characteristics | |
| Copyright © |