IBM MegaRAID 8480 manual Array Performance Features, Fault Tolerance Features

Models: MegaRAID 8480

1 50
Download 50 pages 58.94 Kb
Page 44
Image 44

3.3.2Array Performance Features

Table 3.4 shows the MegaRAID 8480 Storage Adapter array performance

features.

 

 

 

Table 3.4

Array Performance Features

 

 

 

Specification

 

MegaRAID 8480 RAID Controller

 

 

 

PCI Express Host Data Transfer

2.5

Gbits/s per lane

Rate

 

 

 

 

 

 

Drive Data Transfer Rate

3.0

Gbits/s per lane

 

 

Maximum Scatter/Gathers

26 elements

 

 

 

Maximum Size of I/O Requests

6.4

Mbytes in 64 Kbyte stripes

 

 

Maximum Queue Tags per Drive

As many as the drive can accept

 

 

 

Stripe Sizes

 

8, 16, 32, 64, or 128 Kbyte

 

 

 

Maximum Number of Concurrent

255

 

Commands

 

 

 

 

 

 

Support for Multiple Initiators

Yes

 

 

 

 

 

3.3.3Fault Tolerance

Table 3.5 shows the fault tolerance features of the Megaraid 8480

Storage Adapter.

 

Table 3.5

Fault Tolerance Features

 

 

 

Specification

 

MegaRAID 8480 RAID Controller

 

 

Support for SMART1

Yes

Optional Battery Backup for

LSIiTBBU02 battery backup. 4.8V/880mAH

Cache Memory

battery pack; up to 72 hours of data retention

 

 

for 256 Mbytes

 

 

Drive Failure Detection

Automatic

 

 

Drive Rebuild Using Hot Spares

Automatic

 

 

Parity Generation and Checking

Yes

 

 

 

1.The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all predictable disk drive failures. In addition, SMART monitors the internal performance of all motors, heads, and drive electronics.

3-6

MegaRAID 8480 Storage Adapter Characteristics

 

Copyright © 2006-2007 by LSI Corporation. All rights reserved.

Page 44
Image 44
IBM MegaRAID 8480 manual Array Performance Features, Fault Tolerance Features