3.3.4Electrical Characteristics
This subsection provides the power requirements for the MegaRAID 8480 RAID controller. Table 3.6 lists the maximum power requirements.
Table 3.6 | Maximum Power Requirements | ||
|
|
|
|
|
| PCI Express | PCI Express |
RAID Controller | +12 V | +3.3 V | |
|
|
| |
MegaRAID 8480 | 12 W; used only if battery | 9 W | |
|
| is present |
|
|
|
|
|
3.3.5Operating and Non-operating Conditions
For the MegaRAID 8480 RAID controller, the operating (thermal and atmospheric) conditions are:
•Relative humidity range is 5% to 90% noncondensing
•Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the Intel IOP333 processor above the maximum ambient temperature
The parameters for the
•Temperature range: −30 °C to +80 °C without battery backup unit
•Temperature range: 0 °C to +45 °C with LSIiTBBU02 battery backup
3.3.6Safety Characteristics
The MegaRAID 8480 RAID controller meets or exceeds the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier name or trademark, type, and UL flammability rating. The board is installed in a PCI Express bus slot, so all voltages are lower than the SELV 42.4 V limit.
Technical Specifications |
Copyright ©