3. If any error is detected, replace the

FRU

shown by

the FRU code. Rerun the test to verify

that

no more

errors exist.

 

 

Undetermined Problems

You are here because the diagnostic tests did not identify

which adapter or device failed, which installed devices are

incorrect, whether

a short circuit is suspected, or

whether

the system is inoperative. Follow these procedures to

 

isolate the failing

FRU (do not isolate non-defective

FRUs).

Verify that the power supply being used at the time of the failure is operating correctly. (See “Power System

Checkout” on page 10.)

1.Power off the computer.

2.Visually check for damage. If any problems are found, replace the FRU.

3. Remove or disconnect all of the following devices:

a.Non-IBM devices

b. Printer, mouse, and other external devices

c.Battery ASM

d. Hard disk drive

e.DIMM

f. PC Cards (PCMCIA)

4.Power on the computer.

5. Determine if the problem has changed.

6.

If the problem does not recur, reconnect the removed

 

devices

one

at

a

time

until you find the failing FRU.

7.

If

the

problem

remains,

replace

the following FRUs

 

one

at

a time.

Do

not

replace

a non-defective FRU.

 

a.

System board

 

 

 

 

 

b.

LCD

panel

ASM

 

 

 

 

22 ThinkPad 240

Page 27
Image 27
IBM S09N-8590-00 manual Undetermined Problems