SOFTWARE ADJUSTMENT – continued

Select an item using [CH-UP] / [CH-DN] buttons, then set specified value using [RPT/BASE] / [MONI] buttons on the

FRONT PANEL.

ADJUSTMENT

ADJUSTMENT CONDITION

 

 

MEASUREMENT

VALUE

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

1 • LCD display

: A06 HW POWER

 

Rear

Connect the RF power meter to

50.0 W

POWER

• Operating freq. : 160.2750

MHz [GEN74]

 

panel

the [TX] antenna connector.

[Other]

(HI)

 

162.2750

MHz [Other]

 

 

 

 

25.0 W

 

 

• Connect the RF power meter to the [TX]

 

 

 

 

[EUR2], [FRG2]

 

 

antenna connector.

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LOW)

2 • Push the [PROG] button

 

 

 

 

 

10.0 W

 

 

• LCD display

: A06 LW POWER

 

 

 

 

[Other]

 

 

• Operating freq. : 160.2750

MHz [GEN74]

 

 

 

 

5.0 W

 

 

 

162.2750

MHz [Other]

 

 

 

 

[EUR2], [FRG2]

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEVIATION

• LCD display

: A07 LW M DEV

 

Rear

Connect the FM deviation meter

±4.4 kHz [Other]

 

 

• Operating freq. : 160.2750

MHz [GEN74]

 

panel

to the [TX] antenna connector

±3.5 kHz [FRG2]

 

 

 

162.2750

MHz [Other]

 

 

through the attenuator.

 

 

 

• IF bandwidth

: Wide

 

 

 

 

 

 

Connect the audio generator to the [MIC] jack through the JIG cable and set as:

1.0kHz/40 mVrms

Set an FM deviation meter as:

HPF

: OFF

LPF

: 20 kHz

De-emphasis: OFF

Detector

: (P–P)/2

Transmitting

MODULATION

1 • LCD display

: A08 LW LMODC

Rear

Connect the FM deviation meter

±4.4 kHz [Other]

BALANCE

• Operating freq. : 148.2750

MHz [GEN74]

panel

to the [TX] antenna connector

±3.5 kHz [FRG2]

(LOW FRQ.)

 

150.2750

MHz [Other]

 

through the attenuator.

 

 

• IF bandwidth

: Wide

 

 

 

 

Connect the audio generator to the [MIC] jack through the JIG cable and set as:

1.0kHz/40 mVrms

Set an FM deviation meter as:

HPF

: OFF

LPF

: 20 kHz

De-emphasis: OFF

Detector

: (P–P)/2

Transmitting

(HIGH FRQ.)

2 • LCD display

: A09 LW HMODC

±4.4 kHz [Other]

 

• Operating freq. : 171.7250

MHz [GEN74]

±3.5 kHz [FRG2]

 

 

173.7250

MHz [Other]

 

 

• Transmitting

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.