Icom IC-FR3000 manual Software Adjustment

Models: IC-FR3000

1 71
Download 71 pages 31.93 Kb
Page 21
Image 21

4-3 SOFTWARE ADJUSTMENT

Select an item using [CH-UP] / [CH-DN] buttons, then set specified value using [RPT/BASE] / [MONI] buttons on the

FRONT PANEL.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

 

MEASUREMENT

VALUE

 

 

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

1

• LCD display

: A02 LW HRTUN

 

RX

Connect the digital multi meter or

Maximum

SENSITIVITY

 

 

• Connect the standard signal generator

 

oscilloscope to check point

voltage

(HIGH FRQ.)

 

 

to the [RX] antenna connector and set

 

CP18.

 

 

 

 

as:

 

 

 

 

 

 

 

 

 

Frequency

: 171.9250 MHz [GEN74]

 

 

 

 

 

 

 

173.9250 MHz [Other]

 

 

 

 

 

 

Level

: 32 µV*

(–77 dBm)

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

Deviation

: ±3 kHz

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

(MID FRQ.)

 

 

 

 

 

 

 

 

 

2

• LCD display

: A03 LW MRTUN

 

 

 

Maximum

 

 

 

• Connect the standard signal generator

 

 

voltage

 

 

 

to the [RX] antenna connector and set

 

 

 

 

 

 

as:

 

 

 

 

 

 

 

 

 

Frequency

: 160.0750 MHz [GEN74]

 

 

 

 

 

 

 

162.0750 MHz [Other]

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

(LOW FRQ.)

 

 

 

 

 

 

 

 

 

3

• LCD display

: A04 LW LRTUN

 

 

 

Maximum

 

 

 

• Connect the standard signal generator

 

 

voltage

 

 

 

to the [RX] antenna connector and set

 

 

 

 

 

 

as:

 

 

 

 

 

 

 

 

 

Frequency

: 148.0750 MHz [GEN74]

 

 

 

 

 

 

 

150.0750 MHz [Other]

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPEATER

 

 

• LCD display

: A05 LW RPTSQL

 

FRONT

Speaker

Squelch open

SENSITIVITY

 

 

• Connect a standard signal generator to

 

 

 

 

 

 

the [RX] antenna connector and set as:

 

 

 

 

 

 

• Connect the RF power meter or 50

 

 

 

 

 

 

dummy load to the [TX] antenna con-

 

 

 

 

 

 

nector.

 

 

 

 

 

 

 

 

 

Frequency

: 148.0750 MHz [GEN74]

 

 

 

 

 

 

 

150.0750 MHz [Other]

 

 

 

 

 

 

Level

: 0.2 µV* (–121

dBm)

 

 

 

 

 

 

 

 

[Other]

 

 

 

 

 

 

 

: 0.32 µV* (–117 dBm)

 

 

 

 

 

 

 

[EUR2], [FRG2]

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

Deviation

: ±3 kHz

[Other]

 

 

 

 

 

 

 

: ±2.4 kHz

[FRG2]

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

RX UNIT TOP VIEW

CP1 CP18

CP18

RX sensitivity chack point

4 - 6

Page 21