SECTION 4 ADJUSTMENT PROCEDURES

4-1 PREPARATION

Some adjustments must be performed on the “ADJUSTMENT MODE”. CS-FR3000 CLONING SOFTWARE, OPC-478 CLONING CABLE and OPC-592 ADAPTOR CABLE are required when entering the adjustment mode. Refer to the next page in detail.

REQUIRED TEST EQUIPMENT

 

 

 

 

 

 

 

EQUIPMENT

 

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

 

 

 

Output voltage

: 13.6 V DC [FR3000]

Audio generator

Frequency range

: 300–3000 Hz

DC power supply

 

 

13.2 V DC [FR3100]

Output level

: 1–500 mV

 

 

 

 

 

Current capacity

: 25 A or more

 

 

 

 

 

Attenuator

Power attenuation

: 40 or 50 dB

 

 

 

 

 

 

Measuring range

: 1–100 W

Capacity

: 100 W or more

 

 

 

RF power meter

 

Frequency range

: 100–300 MHz

 

 

 

 

 

Frequency range

: 120–600 MHz

(terminated type)

 

Impedance

: 50

Standard signal

 

Output level

: 0.1 µV–32 mV

 

 

SWR

: Less than 1.2 : 1

generator (SSG)

 

 

 

(–127 to –17 dBm)

 

 

 

 

 

 

 

 

Frequency range

: 0.1–600 MHz

 

 

 

Frequency counter

 

AC millivoltmeter

Measuring range

: 10 mV–10 V

 

Frequency accuracy

: ±1 ppm or better

 

 

 

 

 

 

 

 

 

 

Sensitivity

: 100 mV or better

Oscilloscope

Frequency range

: DC–20 MHz

 

 

 

 

Measuring range

: 0.01–20 V

FM deviation meter

 

Frequency range

: DC–600 MHz

 

 

 

 

 

 

Digital multimeter

 

: 10 M/V DC or better

 

 

Measuring range

: 0 to ±5 kHz

Input impedance

 

 

 

 

 

 

 

CONNECTION

Standard signal generator

–127 to –17 dBm

DC power supply

13.6V/25 A [FR3000]

13.2V/25 A [FR3100]

RF power meter 1–100 W / 50

Attenuator

 

FM deviation meter

40 dB or 50dB

 

(DC measurable)

 

 

 

 

Frequency counter

Oscilloscope

[BATTERY] [RX]

Personal computer

RS-232C connector

[MIC]

[TX]

Microphone connector

 

 

 

Audio

 

 

+

 

 

generator

MIC GND

MIC INPUT

 

AC

1

8

 

millivoltmeter

 

 

 

GND

 

PTT

JIG CABLE

OPC-478 + OPC-592