6 SCANS
■Programming scan edge frequencies
A set of scan edge frequencies must be programmed before starting the programmed or auto memory write scans. 10 pairs of scan edges are available: 0P1 to 9P2.
➀Push [PROG] for 1 sec.
•“*SET*” appears in the bank name area, then changes to a flashing “PROG.”
➁Rotate the
edge in a pair e.g. 0P1.
•The keypad can also be used for selection.
➂Set the frequency, mode, tuning step and memory name then push [MW] for 1 sec. to program one of the scan edges.
➃Rotate the
➄Set the frequency then push [MW] for 1 sec. to program.
•Mode, tuning step and name are common to both scan edges.
➅Push [PROG] momentarily to return to the previous channel; or repeat ➁ to ➅ for other scan edges.
| [PROG] | |
| switch | |
| [MW] switch | |
AM | OFF DLY ∞ | |
BANK | kHz | |
*NONAME* | ||
PROG | ||
AM | OFF DLY ∞ | |
BANK | kHz | |
*NONAME* | ||
PROG |
■Scan speed/delay functions
DScan resume condition
Scan pauses when finding a signal, and then resumes or is cancelled depending on the selected scan resume condition. There are 3 resume conditions.
Push [DLY] one or more times to select a resume condition.
• Scan resume OFF∞ Scan pauses until signal disap- OFF DLY pears, then resumes 3 sec. after
that.
Signal | no signal |
|
Scan
scanning
FFDLY ∞
| [DLY D/S ] |
| switch |
receiving a signal | no signal |
pausingscanning
3 sec.
• Scan resume ON with adjusted | |
delay period | OFF DLY ∞ |
Scan pauses | for the adjusted |
delay period after receiving a signal, then resumes. When the received signal disappears, scan resumes approx. 3 sec. after that.
• Scan cancel∞ Scan is cancelled when a signal OFF DLY
is found during scan.
Signal | no signal | receiving a signal | no signal |
|
|
|
Scanpausing
scanningscanning
delay time
Signal | no signal | receiving a signal | no signal |
|
|
| |
Scan | scanning | scan is cancelled |
|
|
|
|
27