UT-102VOICE SYNTHESIZER UNIT

The UT-102 announces the accessed frequency in a clear, electronically generated voice, in English (or Japanese) when pushing [SPCH] or when a signal is detected during scan (see p. 31, 32 for settings).

Under the top cover

Remove the top cover as shown opposite.

Remove the protected paper attached to the bot- tom of the UT-102 to expose the adhesive strip.

Connect the UT-102 as shown in the diagram at right.

Replace the top cover.

UT-102

J12■UT-102VOICE SYNTHESIZER UNIT■FL-52ACW NARROW FILTER

FL-52ACW NARROW FILTER

The IC-R8500 has a CW narrow mode which pro- vides better S/N (signal-to-noise) and also rejects nearby interference. The CW narrow filter is helpful

when receiving CW and radio-teletype signals.

Under the top cover

 

Remove the top cover as shown opposite.

 

Connect the FL-52A as shown in the diagram at

 

right.

 

• Make sure it is connected in the proper orientation.

 

• Attached nuts on the FL-52A are not necessary. If you

 

want to install the filter more securely, open the MAIN

 

unit, then use the nuts on the bottom of the MAIN unit.

 

Replace the top cover.

 