Icom IC-R8500 instruction manual CR-293 HIGH STABILITY CRYSTAL UNIT

Models: IC-R8500

1 48
Download 48 pages 24.44 Kb
Page 42
Image 42
■CR-293HIGH STABILITY CRYSTAL UNIT

12 OPTIONAL INSTALLATIONS

CR-293HIGH STABILITY CRYSTAL UNIT

A temperature-compensating crystal with a stability of ±3 ppm is built-in to the receiver. For more demand- ing operation, the CR-293 HIGH STABILITY CRYSTAL UNIT is available. It has a stability of ±0.5 ppm.

Remove the bottom cover as shown on p. 37.

Remove 6 screws from the metal plate, then remove the metal plate and shield cover.

Remove 10 screws from the PLL unit, then open the unit to expose the bottom.

Unsolder the feet of the internal crystal unit, then remove it.

Place the CR-293 in the space available as shown in the diagram, then solder its feet into place (6 points).

Adjust the reference frequency using a frequency counter.

Replace the ground spring to its original position.

Return the shield cover, metal plate and bottom cover to their original positions.

NOTE: The CR-293 is an oven-type crystal unit, and the specified frequency stability described above is guaranteed 1 min. after power ON.

Ground spring Manual background

Metal plate

Shield cover

PLL unit

CR-293

Internal crystal unit

PLL unit

39

Page 42
Image 42
Icom IC-R8500 instruction manual CR-293 HIGH STABILITY CRYSTAL UNIT