Data Editing Command List
Enter Setup Mode | /E/D/FJ<ENTER> Clear JX<ENTER> |
Review Configuration | JY<ENTER> |
Exit Data Editing | JZ<ENTER> |
Delete Line | JS<ENTER> |
Data Editing | JA<ENTER> |
Enabled | 1<ENTER> |
Disabled | 0<ENTER> |
Unmatched Input | JB<ENTER> |
Do Not Send | 0<ENTER> |
Send | 1<ENTER> |
Code IDs | JC<ENTER> |
Enter JC<ENTER> and the default Code ID(s) from Code ID Definition on page 29.
Set LengthJD<ENTER>
Enter JD<ENTER>and two digits from the keyboard to indicate length.
Match StringJE<ENTER>
Enter JE<ENTER>, one digit <ENTER> one digit <ENTER> for the start position, and the string to match each character, followed by a <EN- TER> (maximum 60 characters).
CountJF<ENTER>
Type JF<ENTER> and enter two digits from the keyboard to indicate the next end of field, each followed by a <ENTER>.
Search StringJG<ENTER>
Enter JG<ENTER> and enter characters for the search criteria from the keyboard or function character chart, each character follo wed by a <ENTER>.
Add FieldJJ<ENTER>
Enter JJ<ENTER> and sequentially the characters to be included in the new field from the keyboard or function character chart, each followed by a <ENTER>.
Send Field SequenceJK<ENTER>
Enter JK<ENTER> and the field ID characters, each followed by <ENTER> in the order to be sent (use upper case alphabetic charac- ters).
Add DelayJM<ENTER>
Enter JM<ENTER> and two digits, each followed by a <ENTER> from the keyboard. Each unit equals 100 milliseconds. Examples
Examples
EXAMPLE ONE
76440057320712
Symbology | Code 128 |
Desired Output: Divide the input data record into two fields with one consisting of the first six digits and the second containing the remain- ing data. The output should have a <ENTER> inserted after each field.
Formula | ID h C 06 A <ENTER> SEND ACBC |
Field List | Field A 764400 |
| Field B 57320712 |
| Field C <ENTER> |
Keystroke Sequence |
|
|
Enter Data Editing Setup |
| /E/D/FJ |
Enter Data Editing and Enable | JA 1 | |
Enter Track_ID and h (for Code 128) | JC h | |
Enter Count and 06 |
| JF 0<ENTER> 6<ENTER> |
Enter Add Field and <ENTER> character | JJ ^N<CR> | |
Enter Field Sequence and ACBC | JKA<ENTER>C< | |
|
| ENTER>B<CR>C<CR> |
Enter Exit Setup |
| JZ |
Output Data | 764400<ENTER> |
|
| 57320712<ENTER> |
4 2 | 4 3 |