ID Tech 50, 25 UPC Settings Enable/Disable UPC-A, Enable/Disable UPC-E, Send Number System Digit

Models: 30 70 60 80 50 25

1 34
Download 34 pages 28.82 Kb
Page 14
Image 14
UPC Settings:

UPC Settings:

Enable/Disable UPC-A

UPC-A is a fixed format symbology and there are no variations allowed. If enabled, UPC-A symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the symbology will be disregarded.

G1<ENTER>A for UPC-A Enable

G1<ENTER>B for UPC-A Disable

Enable/Disable UPC-E

UPC-E is a special version of the UPC-A specification. It is a fixed format symbology and there are no variations allowed. If disabled, the data from the symbology will be disregarded.

G1<ENTER>C for UPC-A Enable

G1<ENTER>D for UPC-A Disable

Send Number System Digit

The first encoded digit in the UPC-A symbol is the number system digit. If enabled, the first digit of the transmitted data stream is the number system digit followed by the manufacturer’s number. If dis- abled, then the first digit transmitted is part of the manufacturer’s number.

G1<ENTER>E for Send Number Digit

G1<ENTER>F for Do Not Send Number Digit

Send Check Digit

The check digit is mandatory in the UPC symbology. If enabled, the reader will send the decoded check digit as the last character in the data stream transmitted. If not, the check character will be suppressed before transmission.

G1<ENTER>G for Send Check Digit

G1<ENTER>H for Do Not Send Check Digit

UPC-E Expansion:

The UPC-E symbology uses a special algorithm to suppress zeros in the encoded data. The suppressed information can be restored by either the Omni reader or the host system. If enabled, the reader will restore the data to its original format. If the host system is set up to do the expansion, then this option should not be used.

G1<ENTER>I for Expand UPC-E

G1<ENTER>J for Do Not Expand UPC-E

Read Two-Digit Addendum

If enabled, the reader will decode the two-digit secondary symbol when it is scanned with the primary symbol, and add the data to the end of the transmission. If not, any two-digit secondary symbol will be ignored.

G1<ENTER>K for Read Two-Digit Addendum

G1<ENTER>L for Do Not Read Two-Digit Addendum

Read Five-Digit Addendum

This option operates in the same manner as the Read Two Digit Addendum option except it enables the reading of a five digit second- ary symbol.

G1<ENTER>M for Read Five-Digit Addendum

G1<ENTER>N for Do Not Read Five-Digit Addendum

2 2

2 3

Page 14
Image 14
ID Tech 50, 25, 60, 30 UPC Settings Enable/Disable UPC-A, Enable/Disable UPC-E, Send Number System Digit, Send Check Digit