ID Tech 30, 25, 60, 50 Addendum Required, Add Separator Space, EAN Settings Enable/Disable EAN-13

Models: 30 70 60 80 50 25

1 34
Download 34 pages 28.82 Kb
Page 15
Image 15
Addendum Required

Addendum Required

If a two or five-digit addendum is enabled, then enabling this option will require an addendum be present before a good read is registered. If not, then symbols with and without the addendum will be accepted.

G1<ENTER>O for Addendum Required

G1<ENTER>P for Addendum Not Required

Add Separator Space

This option is used with the Two and Five-Digit Addendum options. If enabled, an ASCII space character is inserted between the data de- coded from the primary UPC symbol and the addendum symbol.

G1<ENTER>Q to Add Space Separator

G1<ENTER>R to Not Add Space Separator

EAN Settings:

Enable/Disable EAN-13

EAN-13 is a fixed format symbology and there are no variations allowed. If enabled, EAN-13 symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the symbology will be disregarded.

G2<ENTER>A for EAN-13 Enable

G2<ENTER>B for EAN-13 Disable

Enable/Disable EAN-8

If enabled, EAN-8 symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the symbology will be disregarded.

G2<ENTER>C for EAN-8 Enable

G2<ENTER>D for EAN-8 Disable

Send Induced Country Code Character

The EAN symbology adds an extra digit to the beginning of the data to create a two-digit country code. If enabled, the added induced charac- ter is the first character transmitted. If disabled, the induced character is not transmitted.

G2<ENTER>E for Induced Character Enable

G2<ENTER>F for Induced Character Disable

Send Check Digit

The check digit is mandatory in the EAN symbology. If enabled, the reader will send the decoded check digit as the last character in the data stream transmitted. If not, the check character will be suppressed before transmission.

G2<ENTER>G for Send Check Digit

G2<ENTER>H for Do Not Send Check Digit

2 4

2 5

Page 15
Image 15
ID Tech 30, 25, 60, 50, 80 Addendum Required, Add Separator Space, EAN Settings Enable/Disable EAN-13, Enable/Disable EAN-8