ID Tech 25 Industrial 2 of 5 Settings Enable/Disable Industrial 2 of, Fixed Length, Check Digit

Models: 30 70 60 80 50 25

1 34
Download 34 pages 28.82 Kb
Page 12
Image 12
Industrial 2 of 5 Settings:

Industrial 2 of 5 Settings:

Enable/Disable Industrial 2 of 5

If enabled, Industrial 2 of 5 symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the symbology will be disregarded.

F3<ENTER>A for Industrial 2 of 5 Enable

F3<ENTER>B for Industrial 2 of 5 Disable

Fixed Length

Industrial 2 of 5 symbols are commonly printed in a fixed format contain- ing a fixed number of characters. If this option is ON, the first Inter- leaved 2 of 5 symbol scanned after power up will set the length of any other symbols scanned afterwards. If the succeeding scans do not match the length of the first scan, the scan is rejected by the reader. Power must be reset before an Interleaved 2 of 5 symbol of a different length will be accepted.

F3<ENTER>C to Turn Off Fixed Length

F3<ENTER>D to Turn On Fixed Length

Check Digit

When Check Digit is selected, the reader takes the last character in the decoded data stream as a check digit. It then calculates the correct check digit for the remaining data and compares it to the last data character. If it is the same, the data is accepted. If not, the data is rejected. With the Calculate and Send Check Digit option, the reader will send the check digit as part of the data stream. If the Calculate but not Send Check Digit option is selected, the reader will strip it from the data stream before transmission. If the Check Digit is not calculated, the reader will assume the last data character read from the symbol is part of the data stream and will not make a comparison test.

F3<ENTER>E to Not Calculate Check Digit and send whole data stream F3<ENTER>F to Calculate and Send Check Digit

F3<ENTER>G to Calculate but not send Check Digit

Code 128 Setting:

Enable/Disable Code 128

If enabled, Code 128 symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the symbology will be disregarded.

F4<ENTER>A for Code 128 Enable

F4<ENTER>B for Code 128 Disable

Note: The Check Digit is manditory for Code 128.

1 8

1 9

Page 12
Image 12
ID Tech 25 Industrial 2 of 5 Settings Enable/Disable Industrial 2 of, Code 128 Setting Enable/Disable Code, Fixed Length