Chapter 3: Subsystem Monitoring
3.3.1 Default Threshold ValuesTable
4 subsystem. If any of these values are surpassed, the alarm will sound:
| Upper Threshold | Lower Threshold | |
+3.3V | +3.6V | +2.9V | |
+5V | +5.5V | +4.5V | |
+12V | +13.2V | +10.8V | |
CPU Temperature | 90ºC | 5ºC | |
Controller Board | 80ºC | 5ºC | |
Temperature | |||
|
| ||
Enclosure Ambient | 40ºC | 0ºC | |
Temperature | |||
|
|
Table
The thresholds in Table
If any of the following components fails, the audible alarm will be triggered:
•RAID controller module
•Cooling fan modules
•PSU modules
•BBU module
•Hard disk drives
NOTE:
When temperature exceeds a preset threshold, the controller’s charger circuits will stop charging. You will then receive a message that says “Thermal Shutdown/Enter Sleep Mode.” When the temperature falls back within normal range, the battery will resume charging.
|
|
|
Audible Alarm |