Intel D925XCV, D925XBC Location of the Jumper Block, BIOS Setup Configuration Jumper Settings

Models: D925XBC D925XCV

1 112
Download 112 pages 20.27 Kb
Page 80
Image 80
2.9 Jumper Block

Intel Desktop Board D925XCV/D925XBC Technical Product Specification

2.9 Jumper Block

CAUTION

Do not move the jumper with the power on. Always turn off the power and unplug the power cord from the computer before changing a jumper setting. Otherwise, the board could be damaged.

Figure 26 shows the location of the jumper block. The 3-pin jumper block determines the BIOS Setup program’s mode. Table 36 describes the jumper settings for the three modes: normal, configure, and recovery. When the jumper is set to configure mode and the computer is powered- up, the BIOS compares the processor version and the microcode version in the BIOS and reports if the two match.

1

3

 

J6J3

 

OM16682

Figure 26. Location of the Jumper Block

Table 36. BIOS Setup Configuration Jumper Settings

Function/Mode

Jumper Setting

Configuration

Normal

1

3

The BIOS uses current configuration information and

1-2

passwords for booting.

Configure

1

3

After the POST runs, Setup runs automatically. The

2-3

maintenance menu is displayed.

 

 

Recovery

1

3

The BIOS attempts to recover the BIOS configuration. A

None

recovery diskette is required.

 

 