Appendix D — Interfaces

RS-232 Serial Interface

Protocol

Default Setup

Baud rate

9600

Character length

8 bits

Parity

None

Stop bits

1

Handshaking

XON/XOFF and RTS/CTS

To change the Serial settings, see Chapter 5, “Configuring Setup”.

Interface cable

The computer end of the cable depends on the computer model. The printer end is a DB-9pin plug, as shown below.

1 2 3 4 5

6 7 8 9

RS-232 DB9-pins

Signals on the printer’s serial port:

DB-9

Signal

Meaning

 

 

 

1

 

External +5V DC Max 500mA

2

TXD

Transmit data

 

 

 

3

RXD

Receive data

4

 

 

 

 

 

5

GND

Ground

6

 

 

 

 

 

7

CTS

Clear to send

8

RTS

Request to send

 

 

 

9

 

 

 

 

 

76

EasyCoder PD41 Printer User’s Guide