Setting Up ISDN PRI Port Properties
The following table describes DS1 options that can be edited:
Option | Description | |
|
| |
Activate the CSU | This option depends on whether the connection between | |
| the adapter and the T1 line requires a CSU: | |
| • Select Activate the CSU to activate a CSU between | |
|
| the network and the adapter. The CSU is included on |
|
| the |
|
| CSU you must purchase the CSU option. (An external |
|
| CSU is not required). |
| • Deselect Activate the CSU to deactivate a CSU | |
|
| between the network and the adapter. |
| The CSU facility is protected by a password. You must | |
| enter this password when selecting ‘Activate the CSU’ | |
| for the first time. For password instructions, refer to the | |
| Read Me First information provided in your adapter | |
| package. | |
|
| |
Network Line | The Network line build out compensates for the signal | |
Build Out | attenuation due to the length of the cable between the | |
| adapter and the switch. | |
| Four values are available (expressed in dB): | |
| • | 0 |
| • | 7.5 |
| • | 15 |
| • | 22.5. |
| Select the value indicated by your Telco. If this | |
| information is not available, use 0 dB. | |
|
|
|