Configuring the SCSI Bus
Some basic SCSI principles must be applied to correctly configure the SCSI bus on your system.
Termination
Most difficulties with the SCSI bus can be traced to improper termination and cabling.
The SCSI bus must be terminated at both ends, and only at the ends. Configure the termination on your IntraServer CompactPCI® adapter using the configuration information in the preceding chapter. Refer to the documentation for each device on the SCSI bus, to ensure:
1Devices at the ENDS of the bus have TERMINATION ENABLED
2Devices not at the END of the bus have TERMINATION DISABLED
3Use LVD/SE termination on the Ultra2 buses.
4Use active termination for Ultra Wide SCSI.
Automatic SCSI Termination
All IntraServer’s
∙Each SCSI bus must be terminated ONLY at the ends. If the IntraServer
∙If the LVD/SE bus on an