Verifying Correct Installation

Use this procedure to verify installation of your ITI-8000 Series Ultra2 SCSI adapter before booting your system:

1Power on the system.

2When the banner is displayed, press the Stop-A keys to interrupt the boot process and stop at the ok prompt.

3Use the show-devscommand to list the system devices. You should see an output similar to the following:

/SUNW,UltraSPARC-IIi@0,0 /pci@1f,0 /virtual-memory /memory@0,0

/packages

/pci@1f,0/pci@1

/pci@1f,0/pci@1,1

/pci@1f,0/pci@1/pci@1 /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0,1 /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0 /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0,1/tape /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0,1/disk /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0/tape /pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0/disk /pci@1f,0/pci@1,1/network@3,1 /pci@1f,0/pci@1,1/scsi@2 /pci@1f,0/pci@1,1/network@1,1 /pci@1f,0/pci@1,1/ebus@1

ok

/pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0 identifies the FIRST SCSI interface on an IntraServer ITI- 8000 Series adapter

/pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0,1 identifies the SECOND SCSI interface on the IntraServer ITI- 8000 Series adapter

Note: The above are examples. The output of show-devs will vary depending on your system and configuration. Use the corresponding entries on your system, not the ones given here.

If these devices are not listed, check that the adapter is correctly installed, and re-seat the adapter if necessary.

Page 50 of 83