Identifying the SCSI disks

The probe-scsi-all command is used to identify the SCSI devices on your IntraServer adapter.

ok probe-scsi-all

/pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0,1

Target 0

 

 

 

Unit 0

Disk

SEAGATE ST39102LC

0004

Target 1

 

 

 

Unit 0

Disk

SEAGATE ST39102LC

0004

/pci@1f,0/pci@1/pci@1/IntraServer,Ultra2-scsi@0

Target 0

Unit 0 Disk IBM DDRS-34560D DC1B

Target 1

Unit 0 Disk IBM DDRS-34560D DC1B

If the SCSI disks on your IntraServer adapter are not identified by your system, check the following:

1.Does each disk have a unique SCSI ID?

2.Does each disk have an ID that does not conflict with the ID of the IntraServer adapter (Default id = 7)?

3.Is the bus correctly terminated? The IntraServer adapter will automatically terminate the host end of the bus. You must have an SE/LVD terminator at the end of the SCSI chain.

Page 51 of 83