SECTION 10—BATTERIES

Replacing Batteries

NOTE: For this procedure, refer to FIGURE 10.1 on page 54.

NOTE: The following tools are required to perform this procedure:

Wire Cutter

1.Remove the batteries from the wheelchair. Refer to Removing/Installing the Batteries From/Into the Wheelchair on page 55.

2.Cut the tie‐wraps that secure the battery terminal covers to the battery terminals.

3.Slide the RED battery terminal cover back on the RED battery cable to expose the POSITIVE battery terminal.

4.Slide the BLACK battery terminal cover back on the BLACK battery cable to expose NEGATIVE battery terminal.

WARNING

NEVER allow any of your tools and/or battery cable(s) to contact BOTH battery post(s) at the same time. An electrical short may occur and serious personal injury or damage may occur.

5.Remove the locknut that secures the bracket of the POSITIVE battery cable to the POSITIVE (+) battery post of the battery.

6.Remove the locknut that secures the NEGATIVE battery cable to the NEGATIVE(‐) battery post of the battery

7.Discard the existing battery.

8.Position battery connector bracket or wiring harness onto the new 22NF battery as shown.

9.Secure the NEGATIVE battery cable to the NEGATIVE (‐) battery post with existing mounting screw and locknut.

10.Secure the bracket of the POSITIVE battery cable to the POSITIVE (+) battery post with existing mounting screw and locknut.

11.Position each battery terminal cover over top of each battery terminal.

12.Secure battery terminal covers in place with one tie‐wrap.

13.Install batteries into wheelchair. Refer to Removing/Installing the Batteries From/Into the Wheelchair on page 55.

Part No 1154294

53

TDX® SI, TDX SI-HD

Page 53
Image 53
Invacare TDX SI manual Replacing Batteries, Wire Cutter