Page 28

Operation

Model: TM-1400

 

 

 

Operation Mode: 15 Frames/Second

Master Clock: 100.00 MHz, M = 10 nsec

Horizontal Frequency: 15.55 KHz

Pixel Clock:

25 MHz, P = 40 nsec

1H = 64.32 usec

3. External Reset Timing

 

 

 

 

 

External VD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A [1053 H], (67.73 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B [1 H], (64.32 us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal VD

 

 

C [9 H], (578.88 us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D [1044 H], (67.15 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E [ 1053 H], (67.73 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

FDV

 

 

 

 

 

F [13 H], (836.16 us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G [1040 H], (66.89 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Data

H [13 H], (836.16 us)

 

 

I [1040 H], (66.89 ms)

Analog Video

J [10 H], (643.20 us)

K [3 H], (192.96 us)

M [1040 H], (66.89 ms)

L [3 H], (192.96 µs)

4. Async Shutter Reset Timing

VINIT Trigger

N [Variable H], (µs)

 

Internal VD

O [9 H], (578.88 us)

 

 

P [1044 H], (67.15 ms)

 

Q [ 1053 H], (67.73 ms)

R [1 H], (64.32 us)

S [13 H], (836.16 us)

 

FDV

 

T [13 H], (836.16 us)

Digital Data

U [1040 H], (66.90 ms)

V [9 H], (578.88 us)

Analog Video

X [1040 H], (66.89 ms)

W [3 H], (192.96 µs)

TM-1400 Series Progressive Scan Shutter Cameras

Page 35
Image 35
JAI TM-1400 operation manual Async Shutter Reset Timing