Page 26
Operation
TM-1400 Series Progressive Scan Shutter Cameras

Model: TM-1400 Operation Mode: 30 Frames/Second

Master Clock: 100.00MHz, M = 10 nsec

Pixel Clock: 50 MHz, P = 20 nsec

3. External Reset Timing

4. Async Shutter Reset Timing

External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
A
nalog Video

Horizontal Frequency: 31.09KHz

1H = 32.16 usec

A [1053 H], (33.86 msec)
B [1 H], (32.16 us)
C [9 H], (289.44 us)
D [1044 H], (33.58 ms)
E [ 1053 H], (33.86 ms)
K [3 H], (96.48 us)
F [13 H], (418.08 us)
H [13 H], (418.08 us)
J [10 H], (321.60 us)
L [3 H], (96.48µs)
G [1040 H], (33.45 ms)
I [1040 H], (33.45 ms)
M [1040 H], (33.45 ms)
P [1044 H], (33.58 ms)
Q [ 1053 H], (33.86 ms)
U [1040 H], (33.45 ms)
X [1040 H], (33.45 ms)
N [Variable H],(µs)
V [9 H], (289.44 us)
T [13 H], (418.08 us)
W [3 H], (96.48µs)
O [9 H], (289.44 us)
S [13 H], (418.08 us)
R [1 H], (32.16 us)
Delay of internal VD depends on the shutter speed.