Page 26

Operation

Model: TM-1400

Operation Mode: 30 Frames/Second

Master Clock: 100.00MHz, M = 10 nsec

Horizontal Frequency: 31.09KHz

Pixel Clock: 50 MHz, P = 20 nsec

1H = 32.16 usec

3. External Reset Timing

 

External VD

B [1 H], (32.16 us) Internal VD

FDV

Digital Data

A [1053 H], (33.86 msec)

C [9 H], (289.44 us)

D [1044 H], (33.58 ms)

E [ 1053 H], (33.86 ms) F [13 H], (418.08 us)

G [1040 H], (33.45 ms) H [13 H], (418.08 us)

 

I [1040 H], (33.45 ms)

Analog Video

J [10 H], (321.60 us)

K [3 H], (96.48 us)

L [3 H], (96.48µs)

M [1040 H], (33.45 ms)

Delay of internal VD depends on the shutter speed.

4. Async Shutter Reset Timing

VINIT Trigger

N [Variable H],(µs)

 

Internal VD

O [9 H], (289.44 us)

 

 

P [1044 H], (33.58 ms)

R [1 H], (32.16 us)

Q [ 1053 H], (33.86 ms)

S [13 H], (418.08 us)

 

FDV

 

T [13 H], (418.08 us)

Digital Data

U [1040 H], (33.45 ms)

V [9 H], (289.44 us)

Analog Video

X [1040 H], (33.45 ms)

W [3 H], (96.48µs)

TM-1400 Series Progressive Scan Shutter Cameras

Page 33
Image 33
JAI TM-1400 operation manual Async Shutter Reset Timing