Page 30

Operation

Model: TM-1400

Operation Mode: 98.7 Frames/Second

Master Clock: 100 MHz, M= 10 nsec

Horizontal Frequency: 31.09 KHz

Pixel Clock: 50 MHz, P = 20 nsec

1H = 32.16 usec

3. External Reset Timing (Partial Scan 250 Lines)

External VD

 

A [315 H], (10.13 ms)

B [1 H], (32.16 us)

C [9 H], (289.44 µs)

Internal VD

 

 

D [306 H], (9.84 ms)

 

E [ 315 H], (10.13 ms)

FDV

F [65 H], (2.09 ms)

 

 

G [250 H], (8.04 ms)

 

H [65 H], (2.09 ms)

Digital Data

 

 

I [250 H], (8.04 ms)

Analog Video

J [62 H], (1.99 ms)

K [3 H], (96.48 us)

M [250 H], (8.04 ms)

 

L [3 H], (96.48 µs)

 

4. Async Shutter Reset Timing (Partial Scan 250 Lines)

VINIT Trigger

N [Variable H], (µs)

O [9 H], (289.44 µs)

Internal VD

 

 

P [306 H], (9.84 ms)

Q [3 H], ( 96.48 µs)

R [ 315 H], (10.13 ms)

 

S [65 H], (2.09 ms)

 

T [250 H], (8.04 ms)

FDV

Note: For color camera, FDV=252H (async only)

 

U [65 H], (2.09 ms)

Digital Data

 

 

V [250 H], (8.04 ms)

 

W [62 H], (1.99 ms)

Analog Video

 

X [3 H], (96.48 µs)

Y [250 H], (8.04 ms)

 

Z [3 H], (96.48 µs)

TM-1400 Series Progressive Scan Shutter Cameras

Page 37
Image 37
JAI TM-1400 operation manual Async Shutter Reset Timing Partial Scan 250 Lines