Page 29

Operation

Model: TM-1400

Operation Mode: 56.5 Frames/Second

Master Clock: 100 MHz, M= 10 nsec

Horizontal Frequency: 31.09 KHz

Pixel Clock: 50 MHz, P = 200nsec

1H = 32.16 usec

3. External Reset Timing (Partial Scan 500 Lines)

External VD

 

A [550 H], (17.69 ms)

B [1 H], (32.16 us)

C [9 H], (289.44 µs)

Internal VD

 

 

D [541 H], (17.40 ms)

 

E [550 H], (17.69 ms)

FDV

F [50 H], (1.61 ms)

 

 

G [500 H], (16.08 ms)

 

H [50 H], (1.61 ms)

Digital Data

 

 

I [500 H], (16.08 ms)

Analog Video

J [47 H], (1.51 ms)

K [3 H], (96.48 us)

M [500 H], (16.08 ms)

 

L [3 H], (96.48 µs)

 

4. Async Shutter Reset Timing (Partial Scan 500 Lines)

VINIT Trigger

N [Variable H], ( µs)

O [9 H], (289.44 µs)

Internal VD

 

 

P [541 H], (17.40 ms)

 

R [550 H], (17.69 ms)

 

S [50 H], (1.61 ms)

FDV

T [500 H], (16.08 ms)

Note: For color camera, FDV=503H (async only)

 

 

U [50 H], (1.61 ms)

Digital Data

 

 

V [500 H], (16.08 ms)

 

W [47 H], (1.51 ms)

Analog Video

 

X [3 H], (96.48 µs)

Z [500 H], (16.08 ms)

Y [3 H], (96.48 µs)

TM-1400 Series Progressive Scan Shutter Cameras

Page 36
Image 36
JAI TM-1400 operation manual Async Shutter Reset Timing Partial Scan 500 Lines