4. Close the blade cover and secure with four knobs.

 

source, or that the fuses have been removed or break-

Electrical

 

ers tripped in the circuit in which the saw will be

 

connected. Make sure you put a warning placard

Observe the following when connecting to the power

 

on the fuse or circuit breaker to prevent accidental

source. (The cut-off saw wiring diagrams are provided

 

electrical shock.

in Figures 17 and 18.)

2.

If you are installing the motor power cord into a re-

WARNING: JET RECOMMENDS THAT ANY WIRING

 

ceptacle, make sure to use the appropriate plug.

3.

If you are using hard-wired connections to a junc-

INVOLVING HARD WIRING OF THE SAW TO A

 

tion box, connect the wires in the box, and close

BRANCH, ORANY CHANGE OF VOLTAGE SUPPLIED

 

 

the box.

TO THE MOTOR BE PERFORMED BY A LICENSED

 

4.

Install the fuses or reset the breaker.

ELECTRICIAN.

1. Make sure the saw is disconnected from the power

5.

The saw is now ready for service.

 

 

17

Figure 21: Model J-7020 cut-off saw wiring diagram

 

115 Volt

 

 

220 Volt

 

1

3

2

4

1

2

3

4

L1

L2

L1

L2

Figure 22: Connection diagram for 1ph motor

Page 17
Image 17
Jet Tools J-7040 operating instructions Electrical, Model J-7020 cut-off saw wiring diagram