Jotul GZ 550 DV II manual Adjust the Air Shutter See fig, Change the Regulator See fig

Models: GZ 550 DV II

1 32
Download 32 pages 22.29 Kb
Page 18
Image 18
6.Adjust the Air Shutter: See fig. 33.

5.Replace the Burner Tube:. Slip the end of the tube into the Air Shutter and SLIDE TUBE FORWARD TO COMPLETELY COVER THE BURNER ORIFICE.

6.Adjust the Air Shutter: See fig. 33.

Slide the shutter BACK to open the inlet, slide FORWARD to close. The standard settings are: Natural gas - 1/4” open

Propane - 1/2” open

Tighten the wing nut on the Air Shutter Stem.

Replace the Burner Skirt.

7.Change the Regulator: See fig. 34.

Using a Torx T-20 screwdriver or small flat head screwdriver, remove the three specialty screws from the front of the valve regulator.

Remove the regulator tower and gasket.

BE SURE TO REMOVE THE BLACK RUBBER GASKET FROM THE VALVE.

Install the new variable regulator tower with the new rubber gasket. Thoroughly tighten new regulator to valve body.

8.Apply the Conversion Labels:

Apply LABEL A to the cabinet floor so that it may be seen by anyone servicing the fireplace.

Apply LABEL B to the Rating Plate in the space provided.

9.Reassemble the fireplace, apply gas to the system and check for gas leaks including all gas lines before and after the valve. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

IMPORTANT: Correct gas pressure is essential for efficient and safe operation. It is important that the correct gas pressure be established at the time of the installation. For more details, see the Gas Pressure section of this manual on page 12.

WHEN LIGHTING THIS APPLIANCE, ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE BACK COVER OF THIS MANUAL.

Figure 33. Adjust Air Shutter as appropriate. Fully open position is shown here. Slide shutter forward to close.

Be sure to remove the black rubber gasket from the valve.

Apply small conversion notice label here.

Figure 34.

Valve Regulator replacement.

18

Page 18
Image 18
Jotul GZ 550 DV II manual Adjust the Air Shutter See fig, Change the Regulator See fig, Apply the Conversion Labels