Air Shutter Adjustment

Air Shutter Adjustment

1.Open the Lower Grill panel and locate the Air Shutter adjustment stem extending down from the right side of the firebox floor. See figs. 49.

2.Loosen the locknut and push the stem BACK (to the rear of the firebox) to open the air inlet increasing airflow into the burner. Push the stem FORWARD to decrease the air inlet. Make adjust- ments in 1/8” (3 mm) increments and allow time for flame pattern to respond to the new setting. Retighten the locknut when the desired flame pattern is established.

3.Reassemble the fireplace including glass assem- bly. Allow the fireplace to burn 15 -20 minutes on the HIGH setting, observing the flame continu- ously.

4.If the flame appears weak, slow, or sooty, repeat the process described above until the flame is as desired.

Air Shutter Adjustment Stem

Figure 49. Air Shutter adjustment location.

Air Inlet Settings

Natural Gas - 1/4” open Propane - 1/2” open

IMPORTANT: Run the fireplace for a minimum of 15 to 20 minutes to produce an accurate representation of the flame appearance. This warm-up should be done before and between any air shutter adjustment.

Figure 50. Proper flame pattern.

24