Jotul GZ 550 DV II Wall Thermostat Installation, Remote Control, ZG550 Acadia Wiring Diagram

Models: GZ 550 DV II

1 32
Download 32 pages 22.29 Kb
Page 19
Image 19
Wall Thermostat Installation

Wall Thermostat Installation

Use Jøtul Thermostat #129706 or a 750 millivolt DC two-wire circuit thermostat to automatically control your fireplace operation. The thermostat should be placed in the same room as the heater, typically 5’ off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat.

The thermostat should be connected to the Acadia using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.

Connect the two thermostat wire leads to the two lower terminals on the terminal block located to the right of the ON/OFF/T’STAT switch. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Figure 34.

At the thermostat, the two wires should be connected to the two connections screw on the thermostat base plate per the manufacturer’s instructions.

For thermostatic function, place the ON/OFF/T- STAT switch in the T-STAT position and the pilot flame must be lit.

Remote Control

The optional Jøtul Remote Control can be installed on the Acadia gas fireplace. Using the wire sup- plied with the remote, connect the remote directly to the gas control valve. See fig. 36

Connect one receiver lead to the terminal

labelled TH. Connect the other receiver lead to the terminal labeled TH/TP. DO NOT DISCONNECT ANY OTHER WIRES FROM THE VALVE, AND DO NOT OVER TIGHTEN THE TERMINAL SCREWS.

Place the receiver unit under the control valve on the floor of the fireplace cabinet.

CAUTION:

LABEL ALL WIRES PRIOR TO DIS- CONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN- GEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.

ATTENTION:

THERMOPILE

TH Remote Control

TP Figure 36. ZG550 Acadia Wiring Diagram

TH

TP

VALVE

TERMINAL

BLOCK

ROCKER

SWITCH

ON

OFF

STAT

OPTIONAL

THERMOSTAT

or

REMOTE

CONTROL

AU MOMENT DE L’ENTRETIENDES COMMANDES, ETIQUETEZ TOUS LES FILS AVANT LE DEBRANCHEMENT. DES ERREURS DE CABLAGE PEUVENT ENTRAIUN FONCTIONNEMENT INADEQUAT ET DAGEREUX.

Figure 36. ZG550 Acadia Wiring Diagram

19

Page 19
Image 19
Jotul GZ 550 DV II manual Wall Thermostat Installation, Remote Control, ZG550 Acadia Wiring Diagram