JVC DLA-HD10KU/E Terminal Description continued, c External control command table, Numeric value

Models: DLA-HD10KSU/E DLA-HD10KU/E

1 50
Download 50 pages 25 Kb
Page 46
Image 46
Terminal Description (continued)

Terminal Description (continued)

C Parameters used for the data format

The following 3 types of parameters are used for command and response data:

(1) Numeric value (2) ON/OFF (3) Special parameters Each parameter is as follows:

(1) Numeric value

A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters. The range that can be specified is from A8000HB to A7FFFHB

(2) ON/OFF

Shows the status (ON or OFF) of the unit, such as POWER and HIDE.

Character

Hex

Meaning

 

 

 

0

30

OFF

 

 

 

1

31

ON

 

 

 

(3)Special parameters Operation mode parameters

Character

Hex

Meaning

 

 

 

0000

30h 30h 30h 30h

Standby mode

 

 

 

0001

30h 30h 30h 31h

Operate mode

 

 

 

0002

30h 30h 30h 32h

Cool down mode

 

 

 

0004

30h 30h 30h 34h

Emergency mode

 

 

 

cExternal control command table

Function

Command

Asking

 

 

Data Type

 

 

 

 

 

 

 

 

 

Operate mode

ELSE

Numeric Value

 

ON/OFF

Special Data

 

 

 

 

 

 

 

 

Operate

U0F







 

X



 

 

 

 

 

 

 

 

HIDE

U00

X





 

X



 

 

 

 

 

 

 

 

Left/Right Reversal

U17

X





 

X



 

 

 

 

 

 

 

 

Top/Bottom

U18

X





 

X



Inversion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Mode

Z03

X

X



 



X

 

 

 

 

 

 

 

 

Operation mode: Only Asking command is possible

46

Page 46
Image 46
JVC DLA-HD10KU/E Terminal Description continued, c External control command table, C Parameters used for the data format