Adjustments and settings in the menu (continued)

[5] Function

Use this function to set command communications, remote control codes, OFF timer function, etc. You can also reset the lamp time.

Use the UP/DOWN keys to select an adjustment item. Press the [BACK] key to return to the previous screen.

Trigger

Off

Off Timer

Off

High Altitude Mode

Off

Communication Terminal

RS-232C

Network

 

Remote Code

A

Lamp Reset

 

 

 

 

Items

Explanation, operation, precautions, settings

 

 

Trigger

Configures 12V output to an external screen equipped with a trigger function.

 

 

 

 

 

Settings: Off, On(Power), On(Anamo)

[Off]

 

 

 

Off

No output.

 

 

 

 

On (Power)

When turned on, control signals (12V) from the trigger terminal are emitted.

 

 

 

 

 

If you turn off the power, the output of the control signal stops.

 

 

 

 

 

During standby mode, an output will occur if the [OK] button is pressed.

 

 

 

 

 

After cooling, the output stops when you go back to standby.

 

 

 

 

On (Anamo)

Control signals (12V) are emitted when the Anamorphic mode is set from "Off” to “A” or

 

 

 

 

“B”. If the Anamorphic mode is set to "A" or "B", the operation in this state equals "On

 

 

 

 

 

 

 

 

(Power)".

 

 

Off Timer

Sets Off Timer function and its time.

 

 

 

 

 

(*) If there are no operations, the unit powers off automatically.

 

 

 

 

 

(*) It powers off automatically even while projecting an image.

 

 

 

 

 

(*) You will be given a warning 60 seconds before power turns OFF.

 

 

 

 

 

Press the [OK] button while the warning is being displayed to delete the warning display.

 

 

 

 

 

 

 

 

You cannot configure settings to omit warning display.

 

 

 

 

 

Settings: Off, 1 hour, 2 hours, 3 hours, 4 hours

[Off]

 

 

 

Off

Power is not turned off.

 

 

 

 

1 Hour

Power is turned off automatically after 1 hour.

 

 

 

 

2 Hours

Power is turned off automatically after 2 hours.

 

 

 

 

3 Hours

Power is turned off automatically after 3 hours.

 

 

 

 

4 Hours

Power is turned off automatically after 4 hours.

 

 

 

 

 

 

High Altitude Mode

Set to use at low pressure locations (900m above sea level).

 

 

 

 

 

Settings: On, Off

[Off]

 

 

 

On

Set.

 

 

 

 

Off

Do not set.

 

 

 

 

 

 

Communication

Sets the used control terminal. It is not possible to use it at the same time.

 

 

Terminal

Settings: RS-232C, LAN

[RS-232C]

 

 

 

 

 

 

 

 

 

RS-232C

Sets the RS-232C terminal.

 

 

 

 

LAN

Sets the LAN terminal.

 

 

 

 

 

 

 

 

Network

It is displayed, if the setting of the "Communication terminal” to the submenu "[5-1]

 

 

 

 

Network" is set to "LAN".

 

 

Remote Code

Use this function to change the projector's remote control code. The projector can be

 

 

 

 

operated only with a remote control configured with the same code. To change the remote

 

 

 

 

control code itself, press "MENU" and [BACK] together for three seconds or more. All of

 

 

 

 

the buttons on the remote control will begin to blink. Two blinks indicate "Change A to B";

 

 

 

 

three blinks indicate "Change B to A".

 

 

 

 

 

Settings: A, B

[A]

 

 

 

A

Set the projector's remote control code to "A".

 

 

 

 

B

Set the projector's remote control code to "B".

 

 

 

 

 

 

Lamp Reset

Reset of the lamp use time to "0".

 