Menu Configuration (cont.)

Picture Sub Adjust

Configure the standard level of image adjustment.

Item

To do

Setting value

Contrast*1

Adjust the standard level for the contrast adjusted with the CONTRAST knob on the front

–20 to +20

 

 

panel.

 

Bright*1

Adjust the standard level for the brightness adjusted with the BRIGHT knob on the front

–20 to +20

 

 

panel.

 

Chroma*1

Adjust the standard level for the chroma adjusted with the CHROMA knob on the front panel.

–20 to +20

Phase*1,*2

Adjust the standard level for the phase adjusted with the PHASE knob on the front panel.

–20 to +20

NTSC Setup

Select the set-up level of the input NTSC signal.

00 (compliant with 0 %

 

 

 

set-up signal), 7.5 (compliant

 

 

 

with 7.5 % set-up signal)

Component Level

Select the level of the analog component signal (480i and 576i only).

B75 (compliant with

 

 

 

BetacamVTR 7.5 % set-up

 

 

 

signal), B00 (compliant with

 

 

 

BetacamVTR 0 % set-up

 

 

 

signal), SMPTE (compliant

 

 

 

with M2VTR signals)

sub menu

Display the sub menu which enables you to adjust the items in “Picture Sub Adjust” while viewing the actual picture.

reset

Restore the default settings for all the items in “Picture Sub Adjust”.

 

*1

Memorized for each input.

 

*2

When “Component Phase” is set to “Disable,” “Phase” cannot be adjusted if no NTSC signal is input.

 

White Balance Setting

Display the color temperature, and adjusts the drive level and cutoff point of each color (R/G/B).

Item

To do

Setting value

Color Temperature

Select the color temperature. (Cannot be set/changed)

9300K, 6500K, User

R Drive *1

Adjust the drive level of each color (red, green, and blue).

Min – 000 – Max

G Drive

The maximum (Max) and minimum (Min) values vary depending on the input signal or

(in 1024 grades)

B Drive

other settings.

 

R Cut Off *1

Adjust the cutoff point of each color (red, green, and blue).

Min – 000 – Max

G Cut Off

The maximum (Max) and minimum (Min) values vary depending on the input signal or

(in 1024 grades)

B Cut Off

other settings.

 

sub menu

Display the sub menu which enables you to adjust the items in “White Balance Setting” while viewing the actual picture.

reset

Restore the default settings for all the items in “White Balance Setting”.

 

*1 Memorized for each color temperature.

Remote Setting

Settings for the external control.

Item

To do

Setting value

Serial Type

Select a terminal for external control in serial mode.

RS232C, RS485

Parallel Type

Select a control method of the MAKE/TRIGGER terminal.

Make, Trigger, Set

Pin1

 

 

Pin2

Assign the control functions to the pins of the MAKE/TRIGGER terminal.

"Display" in "Functions

Pin3

Assign a function to each pin terminal by selecting “Set” in “Parallel Type” mentioned

controlled by the Make/

Pin4

above.

Trigger system" on page 23

Pin5

 

 

Pin6

The functions are assigned for “Pin6” – “Pin8” and you cannot change the assignment of

Tally

Pin7

these functions.

Enable

Pin8

 

GND

18