JVC GR-DVP3 specifications EN83, Symptom, Possible Causes, Corrective Action

Models: GR-DVP3

1 100
Download 100 pages 57.94 Kb
Page 83
Image 83
EN83

 

 

 

 

EN83

SYMPTOM

 

POSSIBLE CAUSES

 

CORRECTIVE ACTION

 

 

42. The LCD monitor, the

 

42.

 

42. • Wipe them gently with soft

 

viewfinder and the lens have

 

————

 

cloth. Wiping strongly can

 

become dirty

 

 

cause damage ( pg. 84).

 

 

 

 

 

 

(ex. fingerprints).

 

 

 

 

 

 

 

 

 

 

 

 

43. An unusual mark appears.

 

43.

 

43. • Check the section of the

 

 

 

 

————

 

manual that explains LCD

 

 

 

 

monitor/viewfinder indica-

 

 

 

 

 

 

 

 

 

 

 

tions ( pg. 88 – 92).

 

 

 

 

 

 

 

44. An error indication

 

44. • A malfunction of some kind

 

44. • Remove the power supply

 

 

(E01 — E06) appears.

 

has occurred. In this case the

 

(battery pack, etc.) and wait a

 

 

 

camcorder’s functions

 

few minutes for the indication

 

 

 

become unusable.

 

to clear. When it does, you

 

 

 

 

 

can resume using the

 

 

 

 

 

camcorder.

 

 

 

 

 

If the indication remains even

 

 

 

 

 

though you repeat the above

 

 

 

 

 

two or three times, please

 

 

 

 

 

consult your nearest JVC

 

 

 

 

 

dealer.

 

 

 

 

 

 

 

45. The charger indicator on the

 

45. • The temperature of the battery

 

45. • To protect the battery, it is

 

 

AC Power Adapter/Charger

 

is extremely high/low.

 

recommended to charge it in

 

does not light.

 

• Charging is difficult in places

 

places with a temperature of

 

 

 

subject to extremely high/low

 

10°C to 35°C (50°F to 95°F)

 

 

 

temperatures.

 

( pg. 93).

 

 

 

 

 

 

 

46. Picture does not appear on

 

46. • The viewfinder is pulled out.

 

46. • Push the viewfinder back in.

 

 

the LCD monitor.

 

• The LCD monitor's brightness

 

• Adjust the brightness of the

 

 

 

setting is too dark.

 

LCD monitor ( pg. 20).

 

 

 

 

 

• If the monitor is tilted upward

 

 

 

 

 

180 degrees, open the

 

 

 

 

 

monitor fully ( pg. 20).

 

 

 

 

 

 

 

47. When the image is printed

 

47. • This is not a malfunction.

 

47. • By recording with “DIS”

 

 

from the printer, a black bar

 

 

 

activated ( pg. 41) this can

 

appears at the bottom of the

 

 

 

be avoided.

 

screen.

 

 

 

 

 

 

 

 

 

 

 

 

48. When the camcorder is

 

48. • The DV cable was plugged/

 

48. • Turn the camcorder’s power

 

 

connected via the DV

 

unplugged with power turned

 

off and on again, then operate

 

 

 

connector, the camcorder

 

on.

 

it.

 

 

does not operate.

 

 

 

 

 

 

 

 

 

 

 

 

49. The memory card cannot be

 

49.

 

49. • Push in the memory card a

 

 

removed from the

 

————

 

few more times ( pg. 16).

 

camcorder.

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 83
Image 83
JVC GR-DVP3 specifications EN83, Symptom, Possible Causes, Corrective Action