MENU SETTING |
|
| |
MOTION DETECT Screen |
| ||
Settings are executed about the motion detecting function that emits alarm signals when | |||
there exists any motion in the image. Alarm signals are output from the auxiliary terminals on | |||
the back. |
|
|
|
Item |
| Functions and set values | Initial value |
MODE | This sets ON/OFF of motion detecting function. | OFF | |
| OFF: | Motion detecting function does not work. |
|
| ON: | Motion detecting function works. |
|
LEVEL | This sets the level that detects motion. | NORMAL | |
| If the item MODE is set to OFF, “- - |
| |
| settings cannot be changed. |
| |
| To function with large signal level change…decrease the |
| |
| value |
|
|
| To function with small signal level change…increase the |
| |
| value |
|
|
| [Set values: |
|
COMMUNICATION Screen |
| |
Settings are made for the control |
| |
If the setting is changed, be absolutely sure to switch on the power again. |
| |
Item | Functions and set values | Initial value |
STYLE | This sets a communication system according to the system | P TO P |
| used. |
|
| P TO P (Point to point) |
|
| This is set when a remote control unit controls a camera. |
|
| M.DROP |
|
| This is set when a remote control unit controls a plural |
|
| number of cameras. |
|
MACHINE ID | This is set when the STYLE item is set to M.DROP. This | – – – |
| is the number that identifies individual cameras in a group. |
|
| No proper function can be realized if an ID number is |
|
| repeated within a system. |
|
| A combined use with the |
|
| setting together with the video input number of the RM- |
|
| P2580. |
|
| If the item STYLE is set to P TO P, “- - |
|
| settings cannot be changed. |
|
AREA EDIT
ALARM TIME
This sets the range in which the motion detecting function works. ( Page 39)
This sets the output time of the alarm signal output of AUX terminal as well as “ALARM” display on the screen when motion is detected. If the item MODE is set to OFF, “- -
–
10s
MAINTENANCE Screen | |
White spot compensation is performed. | |
Item | Functions and set values |
CCD SPOT | The white spots on the screen, which are characteristic |
| for CCDs can be reduced. |
Page 42 “White Spot Compensation”
Initial value –
MEMO Even when the ALARM TIME item is set to OFF, an alarm signal is output from the AUX terminal for about 500ms, and “ALARM” is not displayed on the screen.
FACTORY SETTINGS Screen |
Set values are returned to initial values. |
DEMONSTRATION | This is used when checking and confirming the set motion | – |
detecting function. The detection area is shown in gray. |
| |
|
| |
| ( Page 39) |
|
Item |
|
|
| Functions and set values |
|
| |
FACTORY | The values set on the menu are returned to initial values. | ||||||
SETTINGS | CANCEL | : | No return to the initial value. |
|
| ||
| CLEAR | : | Returns set values except titles to the | ||||
| (WITHOUT TITLE) |
| initial value. |
|
| ||
| CLEAR (ALL) | : | Returns all set values including titles | ||||
|
|
|
|
| to the initial value. |
|
|
| Select respective set value and press the SET button. | ||||||
| Then, “DATA CLEARED” will appear for about 3 seconds. | ||||||
| Be sure not to switch off the power while the display is still | ||||||
| on. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| MEMO | when FACTORY SETTINGS by means of | ||||
|
| However, | |||||
| transmitted commands, the contents | of | the | ||||
| COMMUNICATION menu do not return to the factory | ||||||
| settings. |
|
|
|
|
Initial value –