INTRODUCTION
Controls, Connectors and Indicators (Continued)
13 | [ | , | , | , | ] |
| right Button |
| |||
| These buttons select items on the menu | ||||
| screen and change a set value. | ||||
| ( Page 23) |
|
14 | |
| Switch of External Synchronization |
| Signal |
| This is a terminating ON/OFF switch for |
| the external synchronization input signal. |
| When this is switched ON, termination is |
| executed via a 75 Ω resistor. |
| ON: terminates at 75Ω. |
| OFF: does not terminate at 75Ω. |
| (ON: At time of factory shipment) |
15 | [INT/GL, LL] Selector Switch for |
17
SIMPLEX: This switch sets to SIMPLEX when the transmission between the camera and a remote control unit is in a simplex system
fi ›
() ⁄
| + | - |
| 1 | 2 |
DC12V | AC24V | CLASS2 ONLY(U TYPE) ISOLATEDPOWER ONLY (E TYPE) |
|
| TX+ TX- RX+ RX- AUX GND |
|
| A B C D |
|
| Y/C OUT |
| SYNC IN | VIDEO OUT |
|
| SEE INST- |
| POWER | RUCTION |
| MANUAL |
‹ | |
|
fl
| TX+ TX- RX+ RX- AUX GND |
| A B C D |
| Y/C OUT |
¤ | VIDEO OUT |
SYNC IN | |
| SEE INST- |
| RUCTION |
POWER | MANUAL |
| |
|
| Synchronizing System |
| This switch sets the synchronizing system |
| for the camera. |
| INT/GL: |
| This is set for internal synchronization |
| (INT) or external synchronization (GL). |
| LL (Line Lock): |
| The camera’s vertical synchronization is |
| locked to the AC 24V power line frequency. |
| When switching between multiple cameras |
| using a switcher, selecting this mode and |
| adjusting the vertical phase can reduce the |
| monitor sync disturbances occur that when |
| the camera image is switched. (This cannot |
| be used in regions where the power |
| frequency is 60 Hz ) (INT/GL: At time of |
| factory shipment) |
16 | [DUPLEX, SIMPLEX] Selector Switch |
| for Transmission System |
| If the setting is changed, be absolutely |
| sure to switch on the power again. |
| DUPLEX: |
| This switch sets to DUPLEX when the |
| transmission between the camera and a |
| remote control unit is in a duplex system |
|
18
control signal cable is set to “ON” and the other cameras are set to “OFF”. In case of the M.DROP system, it becomes necessary to set the Machine ID. ( Page 33) If the system including the camera is the P TO P (Point to Point,
NOT USED This cannot be used. Do not switch.
19 | [DC 12V, AC 24V] Power input terminals | |
|
| |
| To input DC 12V or AC 24V power. | |
20 | [TX+A, | |
| signal connection terminals | |
| Terminals for inputting signals with | |
| electrical characteristics conforming to | |
| the EIA/TIA | |
| 17 RX.TERM switch | |
21 | [AUX, GND] Auxiliary Output Terminals | |
| If any change occurs in the area that was | |
| set on the MOTION DETECT screen, these | |
| terminals output signals. ( Page 32) | |
| ||
| voltage 30V, Current 30mA.] | |
22 | [Y/C OUT] Y/C output connector | |
| This | |
| and chrominance signal. | |
| • Pin configuration of Y/C OUT connector | |
| 4 | 3 |
| 2 | 1 |
| Pin No. | Signal |
| 1 | GND |
| 2 | GND |
| 3 | Luminance (Y) |
| 4 | Chrominance (C) |
23 | [VIDEO OUT] Video signal output |
| connector |
| This BNC connector outputs a composite |
| video signal. Connect this to the video input |
| connector of a video monitor, switcher, etc. |
24 | [POWER] Power indicator lamp |
| This lamp lights when power is supplied |
| to the camera. |
25 | [SYNC IN] Sync signal input connector |
| This BNC connector accepts the input of |
| an external sync signal such as a composite |
| video (VBS) or black burst (BB) signal. |
| When a sync signal is input into this |
| connector, the camera operation is |
| automatically synchronized with the |
| external sync signal. |
| To terminate this connector at 75Ω, turn |
| ON the EXT.TERM switch 14 . |
26 | Power cable |
| Connect to the commercial AC230V |
| outlet |