CONNECTION/INSTALLATION
RM-P2580 System
System with up to 8 cameras
Connecting the control signal cable
(Use a twisted-pair cable for connection. Page 17.)
Camera 1
MACHINE ID:1 (Menu screen) RX TERM: OFF (switch)
Camera
Camera
Control signal cable | ||
Video signal cable | ||
Power | AC24V | |
or | ||
cable | ||
DC12V | ||
| ||
Camera 1 |
|
control signal | |
connection terminals | |
TX+ A | |
TX | B |
RX+ C | |
A RX | + |
B RX | + |
C TX | |
Connect: Camera TX+ to
Camera 2 | AC24V | |
MACHINE ID:2 | ||
or | ||
(Menu screen) | ||
DC12V | ||
RX TERM: OFF | ||
| ||
(switch) |
| |
| Camera | |
|
RX | D |
Camera 2 |
|
control signal | |
connection terminals | |
TX+ A | |
D TX |
Camera RX– to
Camera 8
MACHINE ID:8 (Menu screen) RX TERM: ON (switch)
AC24V | • | • | • | • | • | CAM SW | Time lapse VCR | |
or | ||||||||
|
|
|
|
| OUT | |||
DC12V |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| VIDEO IN |
MONITOR
TX | B |
RX+ C | |
RX | D |
Setting the switches | ( Page 10) |
Remote Control Unit RM-P2580
TO CAMERA
TO CAMERA
- -
POWER
OFF
AC
INPUT
|
|
| CAMERA |
|
|
|
| ||
|
|
|
| SW | COM |
|
| ||
|
|
| DATA I / O |
|
|
|
| ||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| MONITOR |
|
|
|
| VIDEO INPUT |
|
|
|
|
|
|
|
|
|
|
|
| MONITOR MONITOR | OUTPUT 2 | |
|
|
|
|
|
|
| 1 | 2 | |
|
|
|
|
|
|
| OUTPUT OUTPUT |
| |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
|
| VIDEO OUTPUT |
|
|
|
|
|
|
|
|
|
|
|
|
| MONITOR | |
|
|
|
|
|
|
|
| OUTPUT 1 | |
MONITOR
EXT | ON |
INT/GLLL
DUPLEXSIMPLEX
RX | ON |
Select the synchronization method of the camera image. Set the switch on all cameras to LL (Line Lock) and match with the V. PHASE. ( Page 26.)
Set this switch to the DUPLEX
* If the setting is changed, be absolutely sure to |
switch on the power again. |
This is the connected example of the |
|
When controlling with any system except the | |
switches and menu screens according to the systems used. | ( Page 14) |
MEMO |
|
VIDEO
DC
IRIS
NOT USED ![]()
Set this switch to ON (signal termination ON) only on the camera placed at the end of the control signal cable. Set to OFF on all other cameras.
•When operating a system using the
•Confirm switch settings on the screen as follows.MONITOR screen
q Confirm that the image from the camera to be checked | (example showing camera ID as “05”) |
| |
is displayed on the monitor. |
|
w Turn OFF and then ON the AC 24 V power to the cam- |
|
|
|
| |
era to be checked. |
|
|
|
| |
e The camera begins the initial operation and characters |
|
|
|
| |
similar to those shown in the illustration on the right |
|
|
|
| |
appear on the monitor screen. |
|
|
|
| |
r Confirm that “DUPLEX” and |
|
|
|
| |
that the ID number is the correct number (the number | P R O T O C O L : D U P L E X | I D - 0 5 | |||
|
|
|
| ||
should be the same as the number of the VIDEO IN- |
|
|
|
| |
PUT terminal to which the camera is connected on the |
|
|
|
| |
rear panel of the | “DUPLEX” | should | The number shown in the | ||
t If wrong, set the camera ID again. | |||||
be displayed. | □ □ part of | ||||
| should be correct. | ||||
|
| ||||
|
|
|
| ||
Setting on the MENU screen ( Page 33)
* If the setting is changed, escape from the menu screen once, and definitely switch on the power again. | |||
C OMMUN I C A T I O N |
| Set to M.DROP | |
| Set to M.DROP when the | ||
|
| ||
S T YL E | M . DROP | as a remote control unit. When controlling | |
MACH I NE I D | 1 | ||
from another machine, make sure that it | |||
|
| ||
|
| matches the communication system used. | |
MACHINE ID setting switches
Set this item to match the
INPUT terminal number for each camera.
When connecting
●Turn OFF the power supply to all equipment to be used before making connections.
●Carefully read the Instructions for each piece of equipment to be used before making connections.
●For the appropriate connection cables and the length of these, carefully read “Connections on the back” on page 16.
●The control signal cable cannot be used for loop connection.