JVC TK-C1460B instruction manual Connections on the back,  Power supply, TK-C1481BEG AC230V

Models: TK-C1460B

1 42
Download 42 pages 50.67 Kb
Page 31
Image 31

CONNECTION/INSTALLATION

Installing the ferrite core

To retain electromagnetic compatibility, use the ferrite cores provided when connecting to the lens.

MEMO

• If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when

VIDEO

DC

Ferrite core

Wire clamp

Video-iris lens

 

(or galvanometnc-iris lens)

ALC

Av Pk

LEVEL

L H

the unit is at its maximum power consumption. Either use a thick cable to restrict the voltage

drop at the camera side to below 10%, or place the power supply near to the camera. If

voltage drop occurs during operation, the performance will be unstable.

• Attach the cable conductors so that they do not come into contact with the drop prevention

wires.

• Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.

• When using a DC 12 V power supply, ensure that the polarities of the cable are correct.

• The AC 24 V power supply should conform to the following:

TK-C1480BE Isolated power supply only

TK-C1481BEG (AC230V)

Notes:

Install the ferrite cores within 50 mm of the camera-side connectors. (Fasten the ferrite core with the wire clamp provided.)

Power cable connect to the commercial

AC230V outlet

Connections on the back

Power supply

TK-C1480BE (DC 12 V or 24 V)

Connect the DC 12 V or the AC 24 V power

supply to the DC 12V/AC 24V terminals. To

prevent connection errors or a cable

disconnection, we recommend the use of lug

 

Y/C OUT

SYNC IN

VIDEO OUT

 

SEE INST-

 

RUCTION

POWER

MANUAL

 

CAUTION: When you use this camera, the socket-out- let shall be installed near equipment so as to disconnect easily.

 

+

-

 

 

 

 

 

 

 

1

2

ISOLATEDPOWER ONLY

 

 

 

 

 

DC12V

AC24V

CLASS2 ONLY(U TYPE)

TX+

TX- RX+ RX-

AUX GND

TYPE)(E

B

C

D

 

 

 

 

 

A

 

plates for the connections.

The following table shows the connection

distances and connection cables provided

that 2-conductor VVF cables (vinyl-insulated

vinyl sheath cables) are used.

Maximum extension

100 m 260 m 410 m 500 m

(reference)

 

Control signal cables

These cables should be connected only when it is required to control the camera using the RS-442A or RS-485 signals. The use of 0.65 4-conductor twisted pair cables is recom- mended. With these cables, the maximum ex- tension distance is 1,200 m.

Genlock connection

With some systems, when the external sync signal is a composite video or black burst sig- nal genlocking by applying an external sync input requires the horizontal phase (H PHASE) and colour phase (SC COARSE) to be adjusted.

 

Y/C OUT

SYNC IN

VIDEO OUT

 

SEE INST-

POWER

RUCTION

MANUAL

Conductor

1.0mm

1.6mm

2.0mm

2.6mm

diameter

and more

and more

and more

and more

 

 

Connect to the other

MEMO

A

TX+

• Genlocking is not possible with a signal con-

B

TX-

side in pairs like this.

taining too much jitter, such as a VCR or

 

 

 

 

 

 

videodisc playback signal.

C

RX+

Connect to the other

D

RX-

side in pairs like this.

• For details, consult a JVC authorized dealer.

E-16

E-17

Page 31