Introduction

Name of Parts and their Functions (continued)

Q[RX TERM-OFF,ON/INT,LL]Function Selector Switch[RX TERM-OFF,ON]RX Signal Terminal ON/OFF Switch

This sets whether or not the signal between RX+ C and RX- D from the control signal connection terminals L should be terminated at the value of 110K resistance.

ON

:

Terminated at 110K.

OFF

:

Not terminated at 110K.

If the system including the camera is the MULTIDROP (Multi DROP, RS-485) system, only the last camera mounted along the control signal cable is set to AONB and the other cameras are set to AOFFB. (In the case of the MULTIDROP system, it is necessary to set the MACHINE ID.)

If the system including the camera is the P TO P (Point to Point, RS-422A) system, set this switch of all the cameras to AONB. To switch between communication systems, use the item STYLE on the COMMUNICATION screen. (A Pg. 51)

(Default setting: ON)

[NT,LL] Selector Switch for Synchronizing System This switch sets the synchronizing system for the camera.

INT

: This is set for internal synchronization (INT).

LL (Line Lock)

: This is set to synchronize the camera’s vertical

 

synchronization to the power frequency.

 

(Default setting: INT)

R[POWER] Power indicator lamp

This lamp lights up when power is supplied to the camera.

SMounting Screw for Fall Prevention Wire

Use this screw when mounting the fall prevention wire to this unit. (Fall prevention wire is not supplied with this product.)

Note:

Connect the fall prevention wire to prevent this unit from falling accidentally.

TAC 220 V-240 V power cord

This connects the camera to a commercial AC 220 V-240 V socket.

16