Setup

Connecting the back panel (continued)Connecting alarm input/output terminalAlarm input terminal

Connect infrared sensor, door sensor, metal sensor or sensor of manual switch and the like.

To prevent noise from entering the internal circuit, supply non-voltage setting signal.

Do not supply voltage.

Can be set via menu whether to set to alarm when the contact is short (MAKE), or when the contact is open (BREAK). (A Pg. 39)

Supply such that the alarm signal continues for more than 200 ms. The recognition of alarm signal may not be guaranteed if less than 200 ms.

IN

GND

CLASS 2 ONLY(U TYPE)

 

SEE INSTRUCTION

ISOLATED POWER ONLY(E TYPE)

 

 

 

MANUAL

 

 

 

 

POWER

+

-

DC12V d

INT

LL

1

2

AC24V H

RX TERM-OFF

ON

 

 

 

MENU

Z

 

SET

VIDEO OUT

Z Please use a shilded cable.

 

SELECTOR

Alarm output terminal

Connect to alarm devices such as alarm, indicator, light or buzzer.

Open-collector Low signal.

Maximum voltage 25 V, current 30 mA.

AUX

22

GND

24