Setup

Connecting the back panel (continued)Connecting alarm input/output terminalAlarm input terminal

Connect infrared sensor, door sensor, metal sensor or sensor of manual switch and the like.

●To prevent noise from entering the internal circuit, supply non-voltage setting signal.

●Do not supply voltage.

●Can be set via menu whether to set to alarm when the contact is short (MAKE), or when the contact is open (BREAK). (A Pg. 39)

●Supply such that the alarm signal continues for more than 200 ms. The recognition of alarm signal may not be guaranteed if less than 200 ms.

IN

GND

CLASS 2 ONLY(U TYPE)

 

SEE INSTRUCTION

ISOLATED POWER ONLY(E TYPE)

 

 

 

MANUAL

 

 

 

 

POWER

+

-

DC12V d

INT

LL

1

2

AC24V H

RX TERM-OFF

ON

 

 

 

MENU

Z

 

SET

VIDEO OUT

Z Please use a shilded cable.

 

SELECTOR

Alarm output terminal

Connect to alarm devices such as alarm, indicator, light or buzzer.

●Open-collector Low signal.

●Maximum voltage 25 V, current 30 mA.

AUX

22

GND

24