Setup

Connecting the back panel

Connect to AC 24 V or DC 12 V power supply (TK-C1530U/E)

Connect to AC 220 V- 240 V power supply (TK-C1531EG)

CLASS 2 ONLY(U TYPE)

 

SEE INSTRUCTION

ISOLATED POWER ONLY(E TYPE)

 

 

 

MANUAL

 

 

 

POWER

+

-

DC12V d

INT

LL

1

2

AC24V H

RX TERM-OFF

ON

 

 

 

MENU

AUXGNDSET

VIDEO OUT

SELECTOR

Monitor

To the terminal of infrared illumination device etc.(A Pg. 24)

When you install in a place where noise tend to appear, please use a cable with a shield. A shield cable should be connected to a GND terminal.

Connect to the TO CAMERA terminal of RM-P2580E

Connecting the power cableTK-C1530(AC24 V or DC12 V)

Connect the AC 24 V or the DC 12 V power cord to the power input terminal. To prevent connection errors or a cable disconnection, we recommend the use of lug plates.

The following table shows the connection distances when 2-core VVF (vinyl-insulated vinyl sheath cables) are used.

Maximum connection distance

60 m

150 m

240 m

380 m

 

 

 

 

 

Conductor diameter

1.0R and

1.6R and

2.0R and

2.6R and

 

more

more

more

more

 

 

 

 

 

22