1.Remove the camera-mounting bracket fastening screws (x2). The camera-mounting bracket is removed from the camera.

2.Mounting the camera-mounting bracket on top of the camera3.Mounting the camera onto a fixer, pan/tilt unit and the like

Note:

Use a camera-mounting screw with a length shorter than 7 mm from the camera-mounting face. Do not use a screw that is longer than the specified length. It may damage the internal parts.

To mount the camera-mounting bracket on top of the camera, use the screw holes on the back panel.

Fall Prevention

Use the black mounting screw on the back of the camera to install the fall prevention wire

6mm

2mm

M3 x 6mm

UTO

VIDEO

Fall Prevention Wire

Precautions regarding fall prevention

Special attention is required when installing the camera to the wall or ceiling. You should not engage in the installation work yourself. Ask a professional to do the job, since the fall of the camera can result in injuries and accidents.

When installing the camera on a fixer, pan/tilt unit and the like, make sure to install it firmly using a rotation-preventive hole to prevent fall.

To prevent fall, connect the camera to a section with sufficient strength (ceiling slab or channel) using a fall prevention wire.

Pay attention to the length, strength, routing and material (insulation properties) of the fall prevention wire used.

Use the black screw (M3 x 6 mm) on the back of the camera for the installation of the fall prevention wire. Using other screws of different sizes may damage the inside.